The thermocouples, manufactured from MI
thermocouple cables are flexible in design and can penetrate to odd location
where ordinary thermocouple can not approach. The small mass and higher thermal
conductivity enables fast thermal response. Is general , the standard features
and advantages of MIMS cables are
- High Insulation Resistance
Conductor / Sheath and Conductor / Conductor.
- Long Life.
- Easy Installation
- Mechanical Strength
- Safety
- Rapid Response
- Dielectric Strength
- Radiation Resistance
- Corrosion and Scaling
Resistance
- Long Lengths
- Small CableDiameter
Manufacturing Process for MI Cables.
MIMS Cables are manufactured by using a higher diameter tubes and
conductors. The conductors are inserted into metal pipe. The conductors are
properly spaced in the pipe by using crushable Mgo blocks. These Mgo blocks
provides insulation between the conductors as well as with the wall. Also these
blocks maintains the geometry, i.e. the position of conductors. The operation
required to manufacture MIMS cables are
- Cleaning of tubes
- Insertion of conductor into
the bocks
- Host filling (I,e, insertion
of conductors along with the blocks into the pipe)
- Swaging (this operation
crush the MgO blocks)
- Drawing (The diameter is
reduced by successive drawing which also ensures compact powder around the
conductors)
- Inter pass annealing (
Various annealing are required to achieve the metal properties back which are
disturbed in drawing process. This annealing is conducted in controlled
environment to retain the chemical properties of the sheath material)
- Packling and finishing
Techno offers wide range of MI cables for the production of
thermocouples and RTD assembly. The standard OD of cables are 1.6
mm,3mm,4.5mm,6mm and 8mm. They are available with outer sheath of SS304, SS
316l, Inconel 600, Incolloy 800, SS310 and SS 321.
|